Milk Reception & Buffering
Fresh milk from the milking system enters a sanitary buffer tank to stabilize milk flow before continuous transfer to the cooling section, helping avoid frequent start-stop operation of downstream equipment.
Rapid Milk Cooling · Smart PLC Control · Automatic CIP
This page uses a 4 T/h dairy farm milk cooling and storage system as a reference configuration. Final capacity, storage volume, CIP scope and automation level are customized according to herd size, daily milk volume, milking schedule and site conditions.

KEY PROCESS

Fresh milk from the milking system enters a sanitary buffer tank to stabilize milk flow before continuous transfer to the cooling section, helping avoid frequent start-stop operation of downstream equipment.

Milk is transferred through sanitary piping and rapidly cooled through a plate heat exchanger using chilled water before entering storage, reducing the time fresh milk remains at elevated temperature.

Cooled milk is transferred to insulated bulk storage silos with agitation, temperature monitoring and level control for stable refrigerated holding before collection or further processing.

After milk transfer, tanks and connected pipelines can be cleaned through an automatic closed-loop CIP system with programmable cleaning sequences for water, acid, alkali, time and temperature.
OVERVIEW
CORE PERFORMANCE
Integrated Post-Milking System
Dual refrigeration units adjust cooling output to changing milk loads while maintaining stable chilled-water conditions.
25–100% Staged ControlSiemens PLC coordinates milk reception, cooling, storage and CIP with real-time monitoring and automatic fault protection.
PLC · Sensors · Safety InterlocksAutomatic closed-loop cleaning controls water, acid/alkali, time and temperature without dismantling process pipelines.
Closed-Loop · No DisassemblyPROCESS FLOW
Reference workflow for the 4 T/h system. Milk is received and buffered, rapidly cooled through staged plate heat exchange, transferred to insulated storage, and connected tanks and pipelines are cleaned through automatic CIP. Final configuration is customized to actual farm conditions.
CORE EQUIPMENT

Receives fresh milk from the milking system, stabilizes milk flow and transfers it continuously to the rapid cooling section.

Provides rapid post-milking cooling through sanitary milk transfer, plate heat exchange and chilled-water circulation before milk enters refrigerated storage.

Provides insulated refrigerated storage with agitation, temperature monitoring and level detection for cooled milk before collection or further processing.

Provides programmable cleaning for tanks and connected pipelines through controlled circulation routes and automatic cleaning sequences.
CONFIGURATION
CASE STUDIES
KNOWLEDGE
Knowledge article pending
Knowledge article pending
Knowledge article pending
Knowledge article pending
Knowledge article pending
Knowledge article pending
Knowledge article pending
Knowledge article pending
FAQ
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending
Q&A
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending
Content pending